학술대회 Immunity Tests in a Reverberation Chamber using a Correction Factor
Cited 0 time in scopus Download 1 time Share share facebook twitter linkedin kakaostory
저자
곽상일, 황정환, 심동욱, 권종화
발행일
201805
출처
International Symposium on Electromagnetic Compatibility (EMC) 2018/Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC) 2018, pp.70-70
DOI
https://dx.doi.org/10.1109/ISEMC.2018.8394047
협약과제
17HR4300, 전자파잔향실 기반 실환경 전파 측정 및 평가 기술 연구, 권종화
초록
This paper presents an immunity test method using a correction factor to improve an uniformity of an E-field strength in a reverberation chamber. Based on a method in the IEC 61000-4-21, input powers are varied according to stirrer steps to create a uniform field.
KSP 제안 키워드
IEC 61000-4-2, Immunity test, correction factor, e-field, field strength, reverberation chamber, uniform field