학술대회 Analysis of Isotropic Deviation of the Electric-Fields Probe in the Personal Exposure Measurement Meter
Cited 1 time in scopus Download 0 time Share share facebook twitter linkedin kakaostory
저자
곽상일, 김병찬, 최형도
발행일
201210
출처
International Conference on Information and Communication Technology Convergence (ICTC) 2012, pp.235-237
DOI
https://dx.doi.org/10.1109/ICTC.2012.6386826
협약과제
12PR1500, 안전한 전자파환경 조성, 최형도
초록
This paper shows a parameter study of isotropic deviation in the electric-fields probe for the personal exposure measurement meter. To detect the exposed E-fields near the human body, a 3-axis E-fields probe is used in the personal exposure measurement meter. The designed probe is consists of three orthogonal dipole antennas with a diode and a lossy transmission line. The proposed probe bandwidth is 10 MHz to 6 GHz. To accurate measurement of the E-fields, the isotropic radiation pattern of the probe is required. To analyze the isotropic deviation of the E-fields probe with the readout device, a parameter study about dipole height, transmission length and resistor value is performed. © 2012 IEEE.
KSP 제안 키워드
6 GHz, Accurate measurement, Dipole antenna, Dipole height, Human body, Lossy transmission line, Parameter study, Personal exposure, Radiation Pattern, Transmission length