Conference Paper Analysis of CNT Emitter-Based Miniature X-Ray Tubes for Stable and Reliable Operation
Cited 1 time in scopus Share share facebook twitter linkedin kakaostory
Authors
Jun-Tae Kang, Jae-Woo Kim, Sungyoul Choi, Jeongyong Choi, Jin-Woo Jeong, Seungjoon Ahn, Yoon-Ho Song
Issue Date
2013-07
Citation
International Vacuum Nanoelectronics Conference (IVNC) 2013, pp.1-2
Publisher
IEEE
Language
English
Type
Conference Paper
DOI
https://dx.doi.org/10.1109/IVNC.2013.6624761
Abstract
We analyzed the failure mechanism in miniature X-ray tubes with a gated carbon nanotube (CNT) field emitter. The miniature X-ray tube even with a small leakage current of field emission from the CNT emitters to the gate electrode has some distortion of the electron beam trajectory from the cathode to anode passage, causing a charging at insulating parts. The charging at the insulator spacer would lead to an arcing or coupling of the anode and gate electrodes, resulting in a very unstable operation and finally a fatal failure. © 2013 IEEE.
KSP Keywords