학술대회 Analysis of CNT Emitter-Based Miniature X-Ray Tubes for Stable and Reliable Operation
Cited 0 time in scopus Download 0 time Share share facebook twitter linkedin kakaostory
저자
강준태, 김재우, 최성열, 최정용, 정진우, 안승준, 송윤호
발행일
201307
출처
International Vacuum Nanoelectronics Conference (IVNC) 2013, pp.1-2
DOI
https://dx.doi.org/10.1109/IVNC.2013.6624761
협약과제
13IE1200, 세기 조절 마이크로 포커스 멀티엑스선원 기술 개발, 송윤호
초록
We analyzed the failure mechanism in miniature X-ray tubes with a gated carbon nanotube (CNT) field emitter. The miniature X-ray tube even with a small leakage current of field emission from the CNT emitters to the gate electrode has some distortion of the electron beam trajectory from the cathode to anode passage, causing a charging at insulating parts. The charging at the insulator spacer would lead to an arcing or coupling of the anode and gate electrodes, resulting in a very unstable operation and finally a fatal failure. © 2013 IEEE.
KSP 제안 키워드
AND gate, Carbon nano-tube(CNT), Electron beam trajectory, Failure mechanism, Leakage current, Miniature X-ray tube, Small leakage, field emission, field emitter, gate electrode