ETRI-Knowledge Sharing Plaform

KOREAN
논문 검색
Type SCI
Year ~ Keyword

Detail

Conference Paper Simultaneous Color Camera and Depth Sensor Calibration with Correction of Triangulation Errors
Cited 2 time in scopus Share share facebook twitter linkedin kakaostory
Authors
Jae-Hean Kim, Jin Sung Choi, Bon-Ki Koo
Issue Date
2013-07
Citation
International Symposium on Visual Computing (ISVC) 2013 (LNCS 8033), v.8033, pp.301-311
Publisher
Springer
Language
English
Type
Conference Paper
DOI
https://dx.doi.org/10.1007/978-3-642-41914-0_30
Abstract
We propose a new depth correction method for the Kinect through the analysis of the technology behind this sensor. The depth values obtained from the Kinect are sometimes inaccurate because the manufacturer's calibration between IR projector and IR camera becomes invalid by the tolerances in manufacturing, temperature variation and vibration during transportation. To improve the results from the previous methods, an analytic approach is presented in this paper considering that the depth measurement principle of the Kinect is triangulation. Experiments show that the induced depth correction model is reasonable and the results from the proposed approach are better than those of the previous approaches. © 2013 Springer-Verlag.
KSP Keywords
Analytic Approach, Color camera, Correction method, Correction model, Depth measurement, Depth sensor, IR camera, Sensor calibration, Temperature variations, depth correction