학술지 Evaluation of RF Electromagnetic Field Exposure Levels from Cellular Base Stations in Korea
Cited 23 time in scopus Download 0 time Share share facebook twitter linkedin kakaostory
저자
김병찬, 박성욱
발행일
201009
출처
Bioelectromagnetics, v.31 no.6, pp.495-498
ISSN
0197-8462
출판사
John Wiley & Sons
DOI
https://dx.doi.org/10.1002/bem.20585
협약과제
10MR1300, 안전한 전자파환경 조성, 최형도
초록
This article presents the measurement results of human exposure to CDMA800 and CDMA1800 signals at locations in Korea where the general public has expressed concern. Measurements were performed at 50 locations across the country to compare the electromagnetic field levels with the general public exposure compliance limits. At each site, the distances between the nearest single or co-located base station and measurement positions were within a range of approximately 32-422 m. The measured exposure levels were very low compared with the international standard and the Korean human protection notice. The highest field level was 1.5 V/m, which corresponds to 0.15% of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines for human exposure. © 2010 Wiley-Liss, Inc.
KSP 제안 키워드
Cellular base, Co-located, Electromagnetic Field Exposure, International Commission on Non-Ionizing Radiation(ICNIRP), International standard, Ionizing radiation(IR), Radiation Protection, base station(BS), exposure levels, human exposure, measurement results