A Photovoltaic (PV) system needs to monitor individual PV panels to maintain the performance. In a high-dense large-scale PV system, two characteristics can limit the use of communication technology. First, high density can degrade wireless communication performance due to the interference between densely deployed nodes. Second, a large-scale area can limit the communication distance in power line communication (PLC) due to cable loss. This paper proposes a hybrid network using PLC in a local group of PV panels and SUN in a long distance link. A pilot field test shows the feasibility of the proposed hybrid network.
KSP 제안 키워드
Field Test, High-density, Large-scale PV system, Long-distance, Monitoring system, PV Panels, Powerline communication, communication distance, communication technologies, hybrid network, photovoltaic (PV) system