Journal Article Assessment of Measurement Uncertainty for Verification of Compliance with Guidelines for Human Exposure to EMFs from AM Broadcasting Transmitters
Cited - time in scopus Share share facebook twitter linkedin kakaostory
Authors
Byung Chan Kim, Hyung-Do Choi
Issue Date
2015-09
Citation
IEICE Communications Express, v.4, no.9, pp.287-292
ISSN
2187-0136
Publisher
IEICE
Language
English
Type
Journal Article
DOI
https://dx.doi.org/10.1587/comex.4.287
Abstract
In this paper we analyze the uncertainty in measurement when assessing the exposure levels of the general public to RF electromagnetic fields (EMFs) from AM broadcasting transmitters. The purpose of measurement was to evaluate whether human exposure levels are in compliance (or not) with protection guidelines. Six sources of uncertainty were selected, and in order to allow for the propagation characteristics of the middle frequency range, the uncertainties of both the electric and magnetic fields were evaluated. Estimated uncertainties were identical to ±2.34 dB.
KSP Keywords