ETRI-Knowledge Sharing Plaform

KOREAN
논문 검색
Type SCI
Year ~ Keyword

Detail

Journal Article Filter-Free Wavelength Conversion Using Mach-Zehnder Interferometer with Integrated Multimode Interference Semiconductor Optical Amplifiers
Cited 6 time in scopus Download 28 time Share share facebook twitter linkedin kakaostory
Authors
Jong Hoi Kim, Hyun Soo Kim, Eun Deok Sim, Kang Ho Kim, Oh Kee Kwon, Kwang Ryong Oh
Issue Date
2004-08
Citation
ETRI Journal, v.26, no.4, pp.344-350
ISSN
1225-6463
Publisher
한국전자통신연구원 (ETRI)
Language
English
Type
Journal Article
DOI
https://dx.doi.org/10.4218/etrij.04.0103.0131
Abstract
We propose a filter-free wavelength conversion using a Mach-Zehnder interferometer with monolithically integrated 2×2 multimode interference semiconductor optical amplifiers (MMI-SOAs). The device has been optimized by considering a non-homogeneous carrier distribution due to the self-imaging properties of the MMI-SOA. Static measurements show an extinction ratio of up to 18 dB and an input signal rejection ratio of up to 20 dB.
KSP Keywords
Input signal, Mach-Zehnder(MZ), Mach-Zehnder Interferometer(MZI), Multimode interference(MMI), Rejection ratio, Self-imaging, Semiconductor optical amplifiers(SOAs), carrier distribution, extinction ratio, filter-free, imaging properties