ETRI-Knowledge Sharing Plaform

KOREAN
논문 검색
Type SCI
Year ~ Keyword

Detail

Journal Article Effect of Air-Gap Between a Ferrite Plate and Metal Strips on Magnetic Shielding
Cited 26 time in scopus Share share facebook twitter linkedin kakaostory
Authors
Hyun Ho Park, Jong Hwa Kwon, Sang Il Kwak, Seungyoung Ahn
Issue Date
2015-11
Citation
IEEE Transactions on Magnetics, v.51, no.11, pp.1-4
ISSN
0018-9464
Publisher
IEEE
Language
English
Type
Journal Article
DOI
https://dx.doi.org/10.1109/TMAG.2015.2432102
Abstract
This paper explores the effect of an air-gap between a ferrite plate and metal strips on magnetic shielding in the presence of a periodic line current source based on an analytical solution. The Fourier transform is used to represent the magnetic vector potentials in the spectral domain, and the mode-matching technique is enforced to obtain a modal solution in rapidly converging series form, leading to numerically efficient results. Magnetic shielding effectiveness is investigated in terms of the air-gap thickness between the ferrite plate and metal strips, the metal strip width, and the position of a periodic line current source.
KSP Keywords
Air-gap, Analytical Solution, Current source, Magnetic shielding effectiveness, Mode matching(MM), Mode-matching technique, Numerically efficient, Strip width, fourier transform, line current, magnetic vector