Conference Paper A Novel Stress Measurement System with Handhold Electrodes in Massage Chairs
Cited 3 time in scopus Share share facebook twitter linkedin kakaostory
Authors
JeongKyun Kim, Kang Bok Lee, SangYeoun Lee, HoeSung Yang, Sang Gi Hong
Issue Date
2016-10
Citation
International Conference on Information and Communication Technology Convergence (ICTC) 2016, pp.859-863
Publisher
IEEE
Language
English
Type
Conference Paper
DOI
https://dx.doi.org/10.1109/ICTC.2016.7763316
Abstract
In this paper, a novel stress measurement system using electrocardiograph (ECG) in massage chairs is presented. Unlike most of the existing stress monitoring systems, the proposed ECG monitoring system consists of handhold electrodes. We propose two algorithms to reduce main problems of dry and noncontact electrodes from the coupling between the skin and electrodes. Those algorithms are thresholding method based on the median absolute deviation for R-peak detection and reconstruction of missing data using K-Nearest Neighbor algorithm. We show experimental results for the developed stress measurement system.
KSP Keywords