ETRI-Knowledge Sharing Plaform

KOREAN
논문 검색
Type SCI
Year ~ Keyword

Detail

Conference Paper Frequency-Offset Method to Determine Conversion Coefficient of Extremely Low-Frequency Magnetic Field Detector
Cited 0 time in scopus Download 2 time Share share facebook twitter linkedin kakaostory
Authors
Jung-Hwan Hwang, Jong-Hwa Kwon, Hyung-Do Choi
Issue Date
2017-08
Citation
International Symposium on Electromagnetic Compatibility, Signal and Power Integrity (EMCSI) 2017, pp.5-10
Language
English
Type
Conference Paper
DOI
https://dx.doi.org/10.1109/ISEMC.2017.8077832
Project Code
16MR3300, Study on Measurement and Evaluation Technology based on Reverberation Chamber, Kwon Jong Hwa
Abstract
This paper proposes a frequency-offset method to determine a conversion coefficient of an extremely low-frequency magnetic field (ELF-MF) detector to measure the strength of a power-line magnetic field, which is caused by electricity operating at 60 or 50 Hz. Using the frequency-offset method, the conversion coefficient can be determined in spite of interference caused by ambient noise. The frequency-offset method in this paper can be effectively used to develop an ELF-MF detector in a ambient noise environment.
KSP Keywords
50 Hz, Extremely low-frequency magnetic field, Magnetic field(MF), Power Line, ambient noise, frequency offset