Conference Paper Immunity Tests in a Reverberation Chamber using a Correction Factor
Cited 0 time in scopus Download 1 time Share share facebook twitter linkedin kakaostory
Authors
Sang il Kwak, Jung-hwan Hwang, Dong-Uk Sim, Jong Hwa Kwon
Issue Date
2018-05
Citation
International Symposium on Electromagnetic Compatibility (EMC) 2018/Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC) 2018, pp.70-70
Language
English
Type
Conference Paper
DOI
https://dx.doi.org/10.1109/ISEMC.2018.8394047
Project Code
17HR4300, Study on Measurement and Evaluation Technology based on Reverberation Chamber, Kwon Jong Hwa
Abstract
This paper presents an immunity test method using a correction factor to improve an uniformity of an E-field strength in a reverberation chamber. Based on a method in the IEC 61000-4-21, input powers are varied according to stirrer steps to create a uniform field.
KSP Keywords
IEC 61000-4-2, Immunity test, correction factor, e-field, field strength, reverberation chamber, uniform field