학술대회 Electromagnetic Field Exposure Assessment for X-band High Radiated Radar
Cited 0 time in scopus Download 1 time Share share facebook twitter linkedin kakaostory
저자
권덕수, 전상봉, 최형도
발행일
201805
출처
URSI Atlantic Radio Science Meeting (URSI AT-RASC) 2018, pp.1-1
DOI
https://dx.doi.org/10.23919/URSI-AT-RASC.2018.8471365
협약과제
18HR1600, 스마트 사회 전자파 노출량 제어 기반 구축, 최형도
초록
APID5196089. The average received power may be low, however, there is the possibility of exposure to the nearby radar facility because of instantaneous high peak power. The ICNIRP standards recommend for the field strength of pulse wave not exceed 32 times the field strength of frequency dependent acceptable levels, and the IEEE C95.1 standards also recommend on the base on the peak value of pulsed fields [1]. This paper investigates what effect the high radiated pulse radar affects the surrounding area by using ray tracing on a modeling of the nearby environment and in-site measurement.
KSP 제안 키워드
Electromagnetic Field Exposure, Exposure assessment, High peak power, Peak Value, Pulse radar, Pulse wave(PW), Pulsed fields, Ray tracing, Received power, Site measurement, field strength