The power amplifiers for high-speed radio frequency(RF) consume a large amount of power and create thermal burden. Even in the case of power amplifiers based on GaN component devices, which have recently entered maturity in the market and showed an excellent RF power output, the heat flux per module is close to 190 W/cm2, thereby causing thermal management burden. When considering the thermal management of the power module, the direct contact air cooling method using aluminum heat sink or the cooling method using newly designed heat dissipation package structures can be used in unit modules or a small number of array systems. When the number of arrays increases and the power consumption is large, liquid cooling methods, such as maximizing the cooling performance through optimizing the design of the liquid flow path or designing the cooling liquid line as close as possible to the heat source in the power package module, are mainly considered. However, the close contact of the liquid lines to the heat source may form a dewdrop in the package module, thereby reducing reliability especially in the case of a radar system with power array modules. As an alternative, dry cooling methods using heat pipes have been studied, but radar array package modules have not attracted much research attention. In this study, an aluminum flat heat pipe for a 1×4 array module for the RF power amplifier of the next generation X-band radar was developed. This module is lightweight, is based on aluminum material, has a flat shape, and facilitates antenna interconnection through its hole structures. An aluminum flat heat pipe with an antenna interconnection structure was then designed and fabricated, and the temperature limit in the GaN power device and the temperature distribution in the whole package module were evaluated by performing tests in the structure of the 1 × 4 antenna array module and in the condition of 28 W power per module.
KSP 제안 키워드
Close contact, Cooling liquid, Cooling method, Flow path, GaN power device, Generation X, Heat Dissipation, Heat flux, Heat sink, Heat source, High Speed
저작권정책 안내문
한국전자동신연구원 지식공유플랫폼 저작권정책
한국전자통신연구원 지식공유플랫폼에서 제공하는 모든 저작물(각종 연구과제, 성과물 등)은 저작권법에 의하여 보호받는 저작물로 무단복제 및 배포를 원칙적으로 금하고 있습니다. 저작물을 이용 또는 변경하고자 할 때는 다음 사항을 참고하시기 바랍니다.
저작권법 제24조의2에 따라 한국전자통신연구원에서 저작재산권의 전부를 보유한 저작물의 경우에는 별도의 이용허락 없이 자유이용이 가능합니다. 단, 자유이용이 가능한 자료는 "공공저작물 자유이용허락 표시 기준(공공누리, KOGL) 제4유형"을 부착하여 개방하고 있으므로 공공누리 표시가 부착된 저작물인지를 확인한 이후에 자유이용하시기 바랍니다. 자유이용의 경우에는 반드시 저작물의 출처를 구체적으로 표시하여야 하고 비영리 목적으로만 이용이 가능하며 저작물을 변형하거나 2차 저작물로 사용할 수 없습니다.
<출처표시방법 안내> 작성자, 저작물명, 출처, 권호, 출판년도, 이용조건 [예시1] 김진미 외, "매니코어 기반 고성능 컴퓨팅을 지원하는 경량커널 동향", 전자통신동향분석, 32권 4호, 2017, 공공누리 제4유형 [예시2] 심진보 외, "제4차 산업 혁명과 ICT - 제4차 산업 혁명 선도를 위한 IDX 추진 전략", ETRI Insight, 2017, 공공누리 제 4유형
공공누리가 부착되지 않은 자료들을 사용하고자 할 경우에는 담당자와 사전협의한 이후에 이용하여 주시기 바랍니다.