ETRI-Knowledge Sharing Plaform

ENGLISH

성과물

논문 검색
구분 SCI
연도 ~ 키워드

상세정보

학술지 Study on Peak Misdetection Recovery of Key Exchange Protocol using Heartbeat
Cited 6 time in scopus Download 14 time Share share facebook twitter linkedin kakaostory
저자
김주영, 조관태, 김용균, 임경수, 신상욱
발행일
201906
출처
Journal of Supercomputing, v.75 no.6, pp.3288-3301
ISSN
0920-8542
출판사
Springer
DOI
https://dx.doi.org/10.1007/s11227-018-2616-y
협약과제
18ZH1200, 데이터 안심사회를 위한 트러스트 데이터 커넥톰 핵심 원천 기술 개발, 박종대
초록
Various studies have been conducted on a secret key exchange using the inter-pulse interval (IPI) extracted from a pulse wave. The IPI-based key exchange method uses a point where the body can measure an IPI of similar value anywhere. The IPI measured to generate the secret key shares the error correction code between biometric sensors and generates the key using the corrected IPI. Peak misdetection negatively affects key generation because the IPI does not consistently match. In this paper, we propose a method to detect misdetection and recover IPI using thresholds. The proposed method reduces the cost of communication compared to the previous method, which is not only energy efficient but also key generating. The efficiency of the recovery method is also demonstrated. Tests results show the total number of IPI recoveries is 19, while the key generation rate is 99.4%.
KSP 제안 키워드
Biometric sensors, Error correction code, Exchange method, Inter-pulse interval, Key Exchange protocol, Key generation rate, Pulse wave(PW), Recovery method, energy-efficient, secret key exchange, the body