학술대회 A Countermeasure on Frequency Shift of Transmitter for Human Body Communication according to Battery Output Voltage Drop
Cited 0 time in scopus Download 5 time Share share facebook twitter linkedin kakaostory
저자
오광일, 김성은, 강태욱, 이재진, 박형일
발행일
202210
출처
International Conference on Consumer Electronics (ICCE) 2022 : Asia, pp.513-514
DOI
https://dx.doi.org/10.1109/ICCE-Asia57006.2022.9954760
협약과제
22HS1500, IoT기반 엣지컴퓨팅 초저전력 인공지능 프로세서 기술 개발, 이재진
초록
In this paper, an operating frequency shift of the HBC transmitter according to the battery output voltage decreases was analyzed, and an appropriate operating frequency configuration for the HBC transmitter to minimize performance degradation was proposed. The operating frequency shift was measured as 30ppm with the supply voltage range from 3.0V to 2.1V. A frequency calibration was applied to the HBC transmitter to satisfy the CDR lock range that was measured for five HBC receiver samples.
KSP 제안 키워드
Frequency calibration, Human Body Communication(HBC), Operating frequency, Output Voltage, Supply voltage, Voltage Drop, frequency shift, performance degradation, voltage range