Conference Paper Broadband Electromagnetic Attenuation Assessment With a Reconfigurable Testbed Using a Multi-Point Method
Cited - time in scopus Share share facebook twitter linkedin kakaostory
Authors
Chang Hee Hyoung, Jong Hwa Kwon
Issue Date
2026-08
Citation
URSI General Assembly and Scientific Symposium (URSI-GASS) 2026, pp.1-4
Publisher
URSI
Language
English
Type
Conference Paper
DOI
https://dx.doi.org/10.46620/URSIGASS26/ZQAS1276
Abstract
This paper presents a broadband electromagnetic attenuation assessment for unshielded facilities using a reconfigurable testbed. Attenuation is quantified with a validated multi-point spatial-averaging procedure using nine receiving locations inside the assessment volume and a reference measurement in front of the incident plane. The setup follows IEC 61000-4-23:2016/AMD1:2025 for unshielded facilities above 1 GHz and uses two antenna classes—a log-periodic dipole array (LPDA) and a 1–18 GHz double-ridged horn—to extend coverage beyond the LPDA’s 1–6 GHz band. We describe calibration, address antenna interchangeability, and identify an effective horn-based validity limit of 15 GHz based on half-power beamwidth considerations. Measurements show consistent attenuation trends between the LPDA and horn in the overlapping band. Preliminary results indicate that transparent conductive film (TCF) on the incident plane yields attenuation comparable to Low-E building façades reported in prior studies, while aperture cases behave similarly to tempered glass. Overall, the approach enables standards-aligned broadband attenuation characterization of façade-representative unshielded structures with interchangeable antenna systems.
KSP Keywords
15 GHz, 18 GHz, 6 GHz, Broadband attenuation, GHz band, IEC 61000-4-2, Low-E, Point method, Ridged horn, Tempered glass, Transparent conductive film