ETRI-Knowledge Sharing Plaform

KOREAN
논문 검색
Type SCI
Year ~ Keyword

Detail

Conference Paper Camera Calibration from a Single Image based on Coupled Line Cameras and Rectangle Constraint
Cited - time in scopus Share share facebook twitter linkedin kakaostory
Authors
Joo-Haeng Lee
Issue Date
2012-11
Citation
International Conference on Pattern Recognition (ICPR) 2012, pp.758-762
Language
English
Type
Conference Paper
Abstract
Given a single image of a scene rectangle of an unknown aspect ratio and size, we present a method to reconstruct the projective structure and to find camera parameters including focal length, position, and orientation. First, we solve the special case when the center of a scene rectangle is projected to the image center. We formulate this problem with coupled line cameras and present the analytic solution for it. Then, by prefixing a simple preprocessing step, we solve the general case without the centering constraint. We also provides a determinant to tell if an image quadrilateral is a projection of a rectangle. We demonstrate the performance of the proposed method with synthetic and real data.
KSP Keywords